11. INSTALL THE BLOWER (INTERIOR BLOWER) (CONT’D)
Secure the blower by installing 2 more screws into the locations shown in the pictures below (single blower or dual
blower). Reinstall impeller(s) and cover.
Plug the power supply to the 3-prong male connector (A) and
the blower unit into the 2-prong female receptacle (B) inside the
hood.
HE0003
WARNING
Never plug the 2-prong blower cord to the 3-prong power supply cord.
!
FOR DUAL BLOWER UNIT, MAKE
SURE THE IMPELLERS ARE
CORRECTLY INSTALLED, THE HOOD
WILL NOT WORK PROPERLY IF
REVERSED. Both impellers are different
in the dual blower, one rotates clockwise
and the other counterclockwise. Each
wheel and motor have an arrow and a
number on them, you have to match
them correctly (see drawing beside).
Install screws into the location as shown in the pictures below (single blower or dual blower). Do not tighten screws down
fully, leave a 1/8” gap. Hang blower unit onto blower plate (screws through the large part of the keyhole). Slide the blower
to its position (screws in the small part of the keyhole). Tighten the screws.
HD0044
HD0044
Single blower (P5)
Dual blower (P8)
HD0080
HD0081
Single blower (P5)
21
HD0023
FRONT
A
B
Dual blower (P8)
HD0023
1
2