Broan 64000 Ventilation Hood User Manual


 
- 8 -
8. INSTALL THE ADAPTER (INTERIOR BLOWER)
Using two (2) standard 1/2’’ screws, secure the adapter to the top (or back) of the hood. Seal the adapter to the hood
using duct tape.
HD0005
HD0006
9. INSTALL THE HOOD (ALL BLOWERS)
HD0043
INTERIOR BLOWER: Run power cable to installation location. Place the hood to its location. Mark the position of the
screws (smaller part of the key holes) with a pen. Remove the hood and install the (8) 1/2” double thread screws
leaving a 1/8” gap (4 screws for 30” hood). Remove wiring cover, place the wire clamp, insert the cable in the hood and
tighten the wire clamp to secure the cable. Place the hood under the cabinet and slide it in position. Make sure the
adapter/damper assembly enters the ducting. Secure the hood by tightening the screws completely.
EXTERIOR OR IN-LINE BLOWER: Run power cable to installation location. Place the hood to its location. Mark the
position of the screws (smaller part of the key holes) with a pen. Remove the hood and install the (8) 1/2” double thread
screws leaving a 1/8” gap (4 screws for 30” hood). Remove wiring cover on top of the hood and connect wiring (see
instructions included with exterior or in-line blower). Place the hood under the cabinet and slide it in position. Secure
the hood by tightening the screws completely.