Broan E66142SS Ventilation Hood User Manual


 
- 6 -
3. PREPARE THE HOOD (CONT’D)
FOR VERTICAL DISCHARGE ONLY:
The hood is set up at the factory for vertical discharge. Go to step 4 on page 7. Start on step 4.4.
3.5 Remove the metal shutoff plate from the back of the hood, by
removing the 3 screws. Set aside scews.
FOR HORIZONTAL DISCHARGE ONLY:
3.4 From inside the hood, unfold the small retaining tab (A) (located on the edge of the blower opening) on the air
diffuser edge. See pictures below.
HD0109
Folded tab
A
HD0108
A
Unfolded tab
HO0031
HD0119
3.6 Press the metal shutoff plate on a flat surface to completely
flatten bent flange.
HO0032
3.7 From the top of the hood, slide out the plastic air deviator
and discard.
HO0036
3.8 Using the 3 screws removed from 3.5, install the metal shutoff
plate on top of the hood.