Broan K7388 Ventilation Hood User Manual


 
- 10 -
PREPARE THE HOOD
NON - DUCTED CONFIGURATION, cont’d.
7. Carefully place the lower decorative flue
into the recessed area of the range hood
top. Fig. 7.
8. Carefully slide the upper decorative flue
down inside the lower flue.
Note: air vents must be up. Fig. 7.
9. Secure the recirculation plenum to the
upper flue with (4) flat head screws.
Fig. 10.
PLENUM
FIG. 10
4 FLAT
HEAD
SCREWS
UPPER
FLUE
INSTALL THE
HOOD
Note: at least two people
will be required to mount
the hood.
1. Raise the hood into its
mounting position.
2. Plug the power cord into
the electric wall
receptacle. Tuck excess
cord behind the flue.
3. Align the rectangular
opening on the back of
the hood with the wall-
mounting bracket. Gently
lower the hood until it securely engages
the bracket. Fig. 11.
4. Level the hood with 2 mounting screws
(3.9x9.5mm) and secure with (2) mounting
screws. Use drywall anchors provided if
wall studs or framing are not available.
Fig. 11.
5. Mount the plate of the electrical system
attaching it with three mounting screws
(3.9x9.5mm). Fig. 12.
6. Raise the upper flue until its holes align
with holes in the flue mounting bracket
(located on ceiling). Fig. 13.
7. Secure the flue with (2) mounting screws.
Fig. 13.
FIG. 11
3.9x9.5mm
MOUNTING SCREWS
FIG.13
MOUNTING
SCREWS
(4.8x38mm)
MOUNTING
SCREWS
(4.8x38mm)
RECTANGULAR
CUTOUT
WALL FRAMING
MOUNTING
BRACKET
MOUNTING
SCREWS
(3.9x9.5mm)
FIG.12
PLATE OF
THE
ELECTRICAL
SYSTEM
MOUNTING
SCREWS
(3.9x9.5mm)