Broan K7388 Ventilation Hood User Manual


 
- 7 -
FRAMING BEHIND DRYWALL
36-13/16"= bottom of hood 24" above
cooktop
42-11/16"= bottom of hood 30" above
cooktop
36-13/16” to 42-11/16”
above cooktop
INSTALL MOUNTING
BRACKET
1. Construct wood wall framing that is flush
with interior surface of wall studs.
Make sure:
a) the framing is centered over
installation location.
b) the height of the framing will allow the
mounting bracket to be secured to
the framing within the dimensions
shown.
2.
After wall surface is finished, secure
mounting bracket to framing using dimen-
sions shown.
INSTALL FLUE MOUNTING
BRACKET
DUCTED AND NON-DUCTED
1. Assemble the flue mounting bracket,
adjusting outside width as shown. Fig.4
2. Carefully center the mounting bracket
directly over the range hood location.
3. Secure the bracket assembly to the ceiling
using (2) 4.8x38mm mounting screws
and drywall anchors. Make sure the
bracket is pushed into the corner, tight
against the wall and centered over the
hood.
FLUE MOUNTING
BRACKET
10-7/16”
(265.6 mm)
FIG. 4
3.9 x 6 mm
FLAT HEAD
BRACKET SCREWS