Broan Model E662 Cooktop User Manual


 
- 7 -
WARNING
Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with
all applicable codes and standards. Before connecting wires, switch power off at service panel and
lock service disconnecting means to prevent power from being switched on accidentally.
!
9. CONNECT WIRING
10.REINSTALL SIDE PANELS
Reinstall filters.
Reinstall both side panels, using 3 screws per side (saved from step 5), as
shown beside.
HO0042
SCREW LOCATIONS
1
2
3
CAUTION
Remove protective plastic film covering filters before
installing them.
Connect cable into wiring box using provided wire connectors.
Connect wires as follow: WHITE to WHITE (A), BLACK TO BLACK
(B), and GREEN or BARE wires under GREEN ground screws (C).
DO NOT FORGET TO CONNECT THE GROUND.
HE0082
B
A