Page 3
ALLURE
®
QS1 SERIES
RANGE HOOD
➙
➙
PREPARE THE HOOD
3 Remove Wiring Cover from inside the hood. Set cover and
mounting screw aside.
4 Remove either top or back wiring knockout and install
approved
Electrical Cable Clamp.
WIRING
COVER
ELECTRICAL
CABLE CLAMP
Ducted Installation - Skip to Step 10.
The following Steps (5 thru 9) are for
NON-DUCTED INSTALLATION ONLY.
5 Remove Light Panel - held in place with (3) #8 screws
and (2) #8 screws. Disconnect light assembly wire
harness (white connector).
6 Remove Air
Chute - held in
place with one
(1) screw.
NOTE: Be
careful not to
disconnect any
wires.
8 Rotate baffle. Reinsert
baffle into air chute (as
shown) so that baffle
fits all the way into
into air chute. An
audible “click” will
be heard when
fully installed.
This will direct
air flow through
the non-ducted
slots on top
of hood.
9 Re-install air chute and screw,
re-connect wire harness, and replace light panel.
NOTE: Be careful not to trap wires between
Support Fin
and light panel.
AIR CHUTE
SLOTS
7 Remove Baffle
from air chute.
Tabs will
disengage
from
Slots.
SUPPORT FIN
TABS
PREPARE THE HOOD
(3) #8 SCREWS
LIGHT
PANEL
(2) #8 SCREWS
➙
➙
BAFFLE