Broan QS1 Ventilation Hood User Manual


 
Page 4
ALLURE
®
QS1 SERIES
RANGE HOOD
CONNECT WIRING
WARNING: To reduce the risk of electric shock,
make sure power is switched off at the service
panel. Lock or tag service panel to prevent power
from being switched on accidentally.
HOUSE
WIRING
(120 VAC)
CARDBOARD
(Use to protect
cooktop)
1 Connect House Wiring (120 VAC) to hood. Use a piece of
Cardboard to protect the cooktop, if necessary.
2 Connect house black to hood black wire, house white to hood
white wire, and house ground under
Green Ground Screw.
Securely tighten cable clamp onto house wiring.
GREEN
GROUND
SCREW
3 Replace wiring cover.
PREPARE THE HOOD
10 Remove appropriate Duct Knockout(s) from top or back of
hood.
REAR
RECTANGULAR
DUCT KNOCKOUT
(Remove for 3¼” x 10”
Horizontal Discharge)
TOP RECTANGULAR
DUCT KNOCKOUT
(Remove for 3¼” x 10”
Vertical Discharge)
11 3¼” x 10” Ducted Discharge Only: Attach Damper/Duct
Connector over knockout opening. Make sure damper Pivot
is nearest to
Top/Back Edge of hood. Remove Tape from
damper flap.
DAMPER/DUCT
CONNECTOR
(Vertical discharge
position shown)
TAPE
NOTE Damper/Duct Connector can be installed up to 1-inch
on either side of hood center to accomodate off-center
ductwork. In extreme off-center installations, one end of
the duct connector may need to be trimmed to clear the
electrical cable clamp.
TOP/BACK
EDGE
UP TO 1”
SIDE-TO-SIDE
ADJUSTMENT
PIVOT