MAINTENANCE
ALWAYS SWITCH OFF THE ELECTRICITY SUPPLY BEFORE
CARRYING OUT ANY OPERATIONS ON THE APPLIANCE.
Grease Filter
The grease filter should be cleaned frequently. Use a warm detergent
solution. Grease filter is dishwasher safe.
To remove the grease filter: remove the (4) screws and take off the
metal grid. Take off the metal wires and remove the grease filter.
Non-Ducted Recirculation Filter
The Non-Ducted Recirculation filter should be changed every 6
months.
To remove the Non-Ducted Recirculation filter:
1. Remove the grid taking off the (4) “A” screws 3.9x6mm (Fig. 3).
2. Remove the metal wires (Fig. 4) and replace the Non-ducted
recirculation Filter.
Cleaning
Occasional care will help preserve its fine appearance.
• Clean with warm water and mild detergent only.
• Follow all cleaning by rinsing with clear water.
• Wipe dry with clean, soft cloth.
Light bulbs
This range hood requires two 40-Watt light bulbs (not included).
To change bulbs:
1. Remove the 2.9x9.5mm screw securing the light fitting.
2. Pull down lens to remove.
3. Replace with light bulbs of the same type (MAX 40W, 120V,
Candelabra Base Bulb). CAUTION: BULB MAY BE HOT!
SERVICE PARTS
KEY NO. PART NO. DESCRIPTION
5 B03118152 Grid (White)
5 B03127681 Grid (Silver)
9 B08087922 Grease Filter
23 B03295095 Upper Lampholder
24 B03295094 Lower Lampholder
27 B02011270 Metal Wire
28 B02300280 Lampholder
29 B03294794 Light Fitting
230 BE3348475 Controls Closing
236 B02300822 Blower Switch (White)
236 B02300826 Blower Switch (Black)
237 B02300823 Light Switch (White)
237 B02300827 Light Switch (Black)
332 BE3248476 Cover Controls
415 B03202454 Strain Relief Bushing
CAS R730090 Blower Assembly
- B06108604 Socket Assembly
(Includes key No.24, 23, 28)
- - “40 Watt Max.Candelabra
Bulbs not included”
- B08999040 Non-Ducted Filter Kit
(purchased separately)
GREASE
FILTER
METAL WIRES
FIG. 7
FIG. 8