Broan RHVBB20SM Ventilation Hood User Manual


 
GREASE FILTER
METAL WIRES
FIG. 9
SERVICE PARTS
KEY NO. PART NO. DESCRIPTION
4 B03295083 Side Fastener
5 B03118154 Grid
6 B02011013 Spring
9 B08087922 Grease Filter
14 B02300233 Condenser
27 B02011155 Metal Wires
28 B02300280 Lampholder
29 B03293051 Light Fitting
45 BW0000043 Blower
48 B02310203 Motor
49 B03295076 Blower Wheel
53 B03202007 Rubber Washer
86 B08088378 Damper
115 BE3334250 Wiring Box
116 BE3334252 Wiring Box Cover
134 B03295084 Grid Stop
152 B03292200 Wire Clamp
165 B03294780 Controls Box
165 B03295008 Box Condenser
202 B03294779 Runner Wires
222 B03295080 Control Box Cover
223 B03295082 Blower Switch
228 B08086263 Controls Board
229 B03201014 Pilot Lamp
241 B03295081 Light Switch
472 BE3344843 Controls Bracket
472 BE3348478 Right Reflector
473 BE3348555 Left Reflector
AQI B06108607 Switch box Assembly
(Included Key No. 165, 228,
28, 222, 152, 241, 223, 202,
229)
- - “40 Watt Max.Candelabra
Bulbs not included”
- B08999040 Non-Ducted Filter Kit
(purchased separately)
OPERATION
Controls
The light switch turns the lamps on and off.
The blower switch: makes it possible to select the motor operating
speed. Position 0: motor off.
The pilot lamp lights up whenever the blower is on.
MAINTENANCE
ALWAYS SWITCH OFF THE ELECTRICITY SUPPLY BEFORE
CARRYING OUT ANY OPERATIONS ON THE APPLIANCE.
Grease Filter
The grease filter should be cleaned frequently. Use a warm detergent
solution. Grease filter is dishwasher safe.
To remove the grease filter: remove the grid by moving the 2 slide
fasteners “A” (Fig. 2); remove the metal wires and then the grease
filter (Fig. 9).
Non-Ducted Recirculation Filter
The Non-Ducted Recirculation filter should be changed every 6
months.
To remove the Non-Ducted Recirculation filter:
1. Remove the grid by moving the 2 side fasteners “A” (Fig. 2).
2. Remove the metal wires (Fig. 6) and replace the Non-ducted
recirculation Filter.
Cleaning
Occasional care will help preserve its fine appearance.
• Clean with warm water and mild detergent only.
• Follow all cleaning by rinsing with clear water.
• Wipe dry with clean, soft cloth.
Light bulbs
This range hood requires two 40-Watt light bulbs (not included).
To change bulbs:
1. Remove the grid by moving the 2 slide fasteners (A).
2. Replace with light bulbs of the same type (MAX 40W, 120V,
Candelabra Base Bulb). CAUTION: BULB MAY BE HOT!
LIGHT
SWITCH
PILOT LAMP
BLOWER
SWITCH
FIG. 8