5
UK
Telephone Helpline: 0845 146 2887 (United Kingdom)
Tro u bl e s ho o t in g
If your BUFFALO appliance develops a fault, please check the following table before making a call to the
Helpline.
Technical Specifications
Fault Probable Cause Action
The appliance is not working The appliance is not switched on Check the appliance is plugged in correctly
and switched on
Plug and lead are damaged Call BUFFALO agent or qualified technician
Fuse in the plug has blown Replace the plug fuse
Power supply Check power supply
Internal wiring fault Call BUFFALO agent or qualified technician
Thermal cut-out activated Reset thermal cut-out
Safety switch not located properly Refit control/element unit
Appliance does not reach set
temperature
Faulty thermostat Call BUFFALO agent or qualified technician
Faulty element Call BUFFALO agent or qualified technician
Build-up of fat on the element Clean the appliance
Appliance heats up but indicator light
does not come on
Indicator light has expired Call BUFFALO agent or qualified technician
Power indicator light comes on but
appliance does not heat up
Faulty element Call BUFFALO agent or qualified technician
Faulty thermostat Call BUFFALO agent or qualified technician
Thermostat set incorrectly Check thermostat
Appliance slow to heat up Faulty element Call BUFFALO agent or qualified technician
Build-up of fat on the element Clean the appliance
Model Voltage Power Current
Capacity
(litres)
Maximum
single load
(kg)
Dimensions
h x w x d (mm)
Weight
(kg)
L370 230V 50Hz 2000W 8.7A 3 1.2 300 x 180 x 400 4.2
P107 230V 50Hz 2 x 2000W 2 x 8.7A 2 x 3 2 x 1.2 300 x 360 x 400 8.2
L484 230V 50Hz 2800W 12.2A 5 2 300 x 270 x 400 5.8
L485 230V 50Hz 2 x 2800W 2 x 12.2A 2 x 5 2 x 2 300 x 540 x 400 10.8
L490 230V 50Hz 2800W 12.2A 5 2 300 x 283 x 450 7.7
L495 230V 50Hz 2 x 2800W 2 x 12.2A 2 x 5 2 x 2 352 x 550 x 454 14
L300 230V 50Hz 2900W 12.6A 8 3 402 x 283 x 520 8.5
L301 230V 50Hz 2 x 2900W 2 x 12.6A 2 x8 2 x 3 400 x 550 x 500 15.2