Bunn 40119.0000G Coffeemaker User Manual


 
Page 8
COFFEE BREWING
1. Begin each brew cycle with a clean empty brew funnel.
2. Insert a BUNN filter into the funnel.
NOTE: The funnels are equipped with 4 wire loops that can be folded
over top edge of filter if desired, to prevent filter from folding in
during the brew cycle.
3. Pour the fresh coffee into the filter and level the bed of grounds by
gently shaking.
4. Slide the funnel into the funnel rails of the selected side until it
stops.
5. Place an empty server under the funnel.
6. The ON/OFF (Enable Brew) switch for the selected side must be ON.
Select the desired batch size.
7. Momentarily press and release the BREW button. There may be
certain situations in which the brew cycle will not begin when BREW is pressed:
a. SWITCH NOT ON - ON/OFF must be ON.
b. BREW TEMPERATURE TOO LOW - wait until heated or cancel BREW LOCKOUT option.
c. CHECK FUNNEL - remove funnel, empty previously brewed grounds and replace with fresh.
d. DISABLED - select different brew button or batch size.
8. If none of the above messages are displayed, the display will read NOW BREWING and show the time remain-
ing in the brew cycle.
9. Following the brew will be a countdown of drip time DRIPPING which shows the time remaining until the
coffee no longer drips from the funnel tip.
10. Carefully remove the brew funnel and discard the grounds and filter only after visible dripping stops.
Fold over top
edge of filter
40119 010412
READY TEMP - Range: 2° to 20° F (2° to 10° C)
This function allows the operator to set the minimum temperature allowable to start a brew cycle. The range can
be from 2° to 20° F within the set temperature. The water must be at the READY temperature or higher for the
display to indicate READY TO BREW. If brew lockout is enabled, the brewing process will not start below this
READY temperature.
Procedure to set ready temperature:
1. Press and hold the right hidden switch until display reads SET LANGUAGE. Press and release the right hid-
den switch until display reads READY TEMP: XXX°.
2. Using (-) and (+), adjust the ready temperature.
3. When finished, press DONE to save the new setting and to advance to the next function screen, BREW SET-
TINGS ?. Press and release the ON/OFF switch (either on DUAL brewers) to exit programming and return to
the MAIN SCREEN.
TEMPERATURE SELECTION (cont.)
READY TEMP: XXX°
(-) DONE (+)