11
FLAVOR
INPU
T
1
2
WATER
INPUT
REFILL
MAIN
POWER
2 1
1
2
3
3
3
FLAVOR
OUTPUT
FLAV OR
OUTPUT
W
ATER
OUTPUT
F
L
A
VOR
OUT
PUT
W
A
T
ER
OUT
PUT
WATER
OUTPUT
SERVICE
Location:
The fuse holder is located on the lower right front
of the autofill box just to the left of the power cord.
Test Procedure:
1. Disconnect the dispenser from the power source.
2. Remove cap and fuse from fuse holder.
3. Remove fuse from the cap.
4. Check for continuity through the fuse.
If continuity is present, reinstall the fuse, the fuse is
operating properly.
If continuity is not present, replace the fuse.
FIG. 4 FUSE HOLDER
P1516
FUSE AND FUSE HOLDER
Removal and Replacement:
Fuse:
1. Remove the cap from the fuse holder.
2. Remove fuse from the fuse holder and inspect. If
blown, discard.
3. Install new 10 amp fuse in the fuse holder.
4. Reinstall fuse holder cap.
Fuse Holder:
1. Disconnect the dispenser from the power source.
2. Disconnect the wires from the rear of the fuse
holder.
3. Remove the nut securing the fuse holder to the
front of the main mounting panel.
4. Push the fuse holder through the hole in the
panel.
5. Install new fuse holder and fuse through the hole
in the panel.
6. Secure the fuse holder to the panel.
7. Refer to Fig. 5 and reconnect the wires.
BLKfromMain
Wiring Harness
BLKtoMain
ON/OFF Switch
FIG. 5 FUSE HOLDER TERMINALS
P1331
41093 040408