Bunn CDBC-TS Coffeemaker User Manual


 
Page 5
OPERATING CONTROLS
Model CEZ-APS/TS/TSR
ON/OFF SWITCH
Placing the "ON/OFF" switch in the "ON" upper position enables the
brew circuit, and energizes the tank refill circuit. Placing the switch
in the "OFF" lower position stops tank refilling and brewing. Stop-
ping a brew cycle after it has been started will not stop the flow of
water into the server until the funnel is empty.
NOTE – Hot water will be available at the faucet in a limited amount
when the switch is in the "OFF" position because the tank will not
refill.
ON/OFF SWITCH
Pressing the "ON/OFF" switch (indicator glowing) enables the brew
circuit and energizes the tank refill circuit. Pressing the switch again
(indicator not glowing) stops tank refilling and brewing. Stopping a
brew cycle after it has been started will not stop the flow of water into
the server until the funnel is empty.
NOTE – Hot water will be available at the faucet in a limited amount
when the "ON/OFF" indicator is not glowing because the tank will not
refill.
BREW SWITCH
Momentarily pressing and releasing the switch starts a brew cycle when the "ON/OFF" switch is in the "ON" upper
position.
NOTE – The "ON/OFF" switch must be in the "ON" upper position to initiate and complete a brew cycle.
READY INDICATOR
This indicator glows when the preselected brew water temperature has been achieved.
Model CDBC-APS/TS/TSR
BREW SWITCH
Momentarily pressing and releasing the switch starts a brew cycle when the "ON/OFF" indicator is glowing.
NOTE – The "ON/OFF" indicator must be glowing to initiate and complete a brew cycle.
READY INDICATOR
This indicator glows when the preset temperature has been achieved. The word "NOT" above "READY" will glow
in all other instances.
TEMPERATURE INDICATORS (Feature disabled from the factory – refer to page 8.)
The indicator glows to communicate the brew water temperature. Two indicators will glow when the
temperature is between them.
P1911
P1910