Bunn CWT-TS Coffeemaker User Manual


 
Page 23
SERVICE (cont.)
TIMER (cont.)
with a voltmeter when the "ON/OFF" switch is in
the "ON" position (upper) and start switch pressed.
Connect the brewer to the power source. The
indication must be 120 volts ac for two wire 120
volt models and three wire 120/240 volt models.
6. Disconnect the brewer from the power source.
7. Reconnect the three pin connector from main
wiring harness to the timer.
If voltage is present as described, proceed to #8
If voltage is not present as described, refer to Wiring
Diagrams and check the brewer wiring harness.
8. Disconnect on black and white wires to the sole-
noid.
9. Check the voltage across the black and white
wires with a voltmeter when the "ON/OFF" switch
is in the "ON" position (upper) and the "START"
switch is pressed to the "START" position (lower)
and released. Connect the brewer to the power
source. The indication must be 120 volts ac for
approximately 20 seconds for two wire 120 volt
models and three wire 120/240 volt models.
If voltage is present as described, the brew timer is
operating properly. Reset the timer dial as required,
to obtain the desired brew volume.
If voltage is not present as described, replace the
timer.
Removal and Replacement:
1. Disconnect the timer socket from the brewer
wiring harness and the timer leads from the
solenoid valve.
2. Remove the one #8-32 screw securing timer to
component bracket.
1
2
3
4
5
.5
MINUTES
BUNN-O-MATIC
P/N 2235-120 VAC
To Main Wiring Harness
WHI to Solenoid Valve
BLK to Solenoid Valve
P1136
3 Install new timer on component bracket securing
with one #8-32 screw.
4. Refer to the illustration below when reconnect-
ing the wires.
5. Readjust the timer dial as required.