Page 6
INITIAL SET-UP
CAUTION - The brewer must be disconnected from the power source throughout the initial set-up, except
when specifi ed in the instructions.
1. Insert an empty funnel into the funnel rails.
2. Place an empty dispenser under the funnel.
3. Place the heater switch at the rear of the brewer in the "OFF" lower position.
4. Connect the brewer to the power source, place the "ON/OFF" switch in the "ON" upper position, and momentarily
press and release the start switch. Water will begin fl owing into the tank. When water stops fl owing into
the tank, initiate a second and a third brew cycle. During the third brew cycle the tank will fi ll to its capacity
and the excess will fl ow from the sprayhead, out of the funnel, and into the dispenser.
5. When the fl ow of water from the funnel stops, place the heater switch at the rear of the brewer in the "ON"
upper position and wait approximately twenty minutes for the water in the tank to heat to the proper tempera-
ture. Some water will drip from the funnel during this time; this is due to expansion and should not occur
thereafter.
6. Empty the dispenser, place the "ON/OFF" switch in the "ON" upper position, and momentarily press and release
the start switch.
7. Place the "ON/OFF" switch in the lower "OFF" position after water has stopped fl owing from the funnel, and
let the water in the tank reheat to the proper temperature.
8. Empty the dispenser, place the "ON/OFF" switch in the "ON" upper position, and momentarily press and release
the start switch. Check the water volume in the dispenser after water has stopped fl owing from the funnel.
It should be 64 ounces.
9. If not, adjust the timer as required. Refer to Adjusting Brew Volumes.
10. Repeat steps 8 & 9 until 64 oz water volume is achieved.
NOTE: Repeat steps 1 through 10 for the other side.
11. The brewer is now ready for use in accordance with the coffee brewing instructions on the next page.
10737 100801
ADJUSTING BREW VOLUMES
CAUTION - Disconnect the power source from the brewer prior to the removal of any panel for the replacement
or adjustment of any component.
NOTE: Prior to setting or modifying batch sizes, check that the brewer is connected to water supply, the tank is
properly fi lled, and a funnel and server are in place.
1. Modifying batch sizes. To modify a batch volume, fi rst check that the SET/LOCK switch is in the "SET" posi-
tion on the circuit board.
To increase a batch size. Press and hold the START or BREW switch until three clicks are heard. Release
the switch (Failure to release the switch within two seconds after the third click causes the volume setting to
be aborted and previous volume setting will remain in memory) and press it again one or more times. Each
time the switch is pressed, two seconds are added to the brew time period. Allow the brew cycle to fi nish in
order to verify that the desired volume has been achieved.
To decrease a batch size. Press and release the START or BREW switch once for every two-second interval
to be removed from the total brew time period; then immediately press and hold down the START or BREW
switch until three clicks are heard. Release the switch. (Failure to release the switch within two seconds after
the third click causes the volume setting to be aborted and previous volume setting will remain in memory).
Allow the brew cycle to fi nish in order to verify that the desired volume has been achieved.