Page 13
TROUBLESHOOTING (cont.)
PROBLEM
Weak beverage
Dry coffee grounds remain in the
funnel
Brewer is making unusal noises
(CWT-APS, CWTF-APS, CWT-TS,
CWTF-TS, CWT-TSR, CWTF-TSR)
PROBABLE CAUSE
1. Filter Type
2. Coffee Grind
3. Sprayhead
4. Funnel Loading
5. Water Temperature
1. Funnel Loading
1. Solenoid
2. Plumbing Lines
3. Water Supply
REMEDY
BUNN® paper filters must be
used for proper extraction.
A fine or drip grind must be used
for proper extraction.
A six-hole stainless steel spray-
head must be used for proper
extraction.
The BUNN® paper filter must be
centered in the funnel and the bed
of ground leveled by gentle shak-
ing.
Place an empty funnel on an empty
dispenser beneath the sprayhead.
Initiate a brew cycle and check the
water temperature immediately
below the sprayhead with a ther-
mometer. The reading should not
be less than 195°F. Adjust the
control thermostat to increase the
water temperature. Replace if nec-
essary.
The BUNN® paper filter must be
centered in the funnel and the bed
of grounds leveled by gently shak-
ing.
The nut on the solenoid must be
tight or it will vibrate during op-
eration.
Plumbing lines should not resting
on the counter top.
(A) The brewer must be connected
to a cold water line.
(B) Water pressure to the brewer
must not exceed 90 psi (620 kPa).
Install a regulator if necessary to
lower the working pressure to ap-
proximately 50 psi (345 kPa).
10690 021800