Bunn CWT-TSR Coffeemaker User Manual


 
Page 4
ELECTRICAL REQUIREMENTS
CAUTION - The brewer must be disconnected from the power source until specified in
Initial Set-Up.
Model 15 has an attached cordset and requires 2-wire grounded service rated 120 volts ac, 15 amp, single
phase, 60 Hz.
Model 35 requires 3-
wire, grounded service
rated 120/208 or 120/240
volts ac, 20 amp, single
phase, 60 Hz. Proceed as
follows:
Model 20 requires 2-
wire, grounded service
rated 120 volts ac, 20
amp, single phase, 60 Hz.
Proceed as follows:
Electrical Hook-Up
CAUTION – Improper electrical installation will damage electronic components.
1. An electrician must provide electrical service as specified.
2. Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.
3. Place the heater switch at the rear of the brewer in the OFF lower position.
4. Remove the front panel beneath the sprayhead.
5. Feed the cord through the strain relief and connect it to the terminal block.
6. Connect the brewer to the power source and verify the voltage at the terminal block before proceeding. Replace
the front panel.
7. If plumbing is to be hooked up later be sure the brewer is disconnected from the power source. If plumbing
has been hooked up, the brewer is ready for Initial Set-Up.
“A" & "B” models re-
quire 2-wire, grounded
service rated 200 volts ac
or 240 volts ac, 20 amp,
single phase, 50 Hz. Pro-
ceed as follows:
PLUMBING REQUIREMENTS
Models CW-APS & CWT-TS:
These models are completely portable and require no attached plumbing.
Models CWT-APS, CWTF-APS, CWT-TS, CWTF-TS, CWT-TSR & CWT-TSR
These brewers must be connected to a cold water system with operating pressure between 20 and 90 psi (138
and 620 kPa) from a
1
2" or larger supply line. A shut-off valve should be installed in the line before the brewer. Install
a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce it to 50 psi (345 kPa). The water
inlet fitting is
1
4" flare.
NOTE - Bunn-O-Matic recommends
1
4" copper tubing for installations of less than 25 feet and
3
8" for more than
25 feet from the
1
2" water supply line. A tight coil of copper tubing in the water line will facilitate moving the brewer
to clean the countertop. Bunn-O-Matic does not recommend the use of a saddle valve to install the brewer. The
size and shape of the hole made in the supply line by this type of device may restrict water flow.
This equipment must be installed to comply with the Basic Plumbing Code of the
Building Officials and Code Administrators International, Inc. (BOCA)
and the Food Service Sanitation Manual of the Food and Drug Administration (FDA).
"B” models require 2-
wire, grounded service
rated 100 volts ac, 20
amp, single phase, 50 Hz.
Proceed as follows:
10690 021800
WHITE
NEUTRAL
L1 BLACK
120V A.C.
L2 RED
WHITE
NEUTRAL
L1 BLACK
120V A.C.
120V A.C.
208 OR 240V A.C.
WHITE
NEUTRAL
L1 BLACK
100V A.C.