MAIN SCREEN
This screen will be shown when the brewer is ready
for use. The screen displays the water temperature
in the tank. When the water in the tank reaches the
correct set temperature, the display will change from
HEATING to READY TO BREW.
PROGRAMMING LOCKOUT SWITCH (mounted on
main control board)
This switch can be set to prevent access to the
programming levels of the brewer. Once all the cor-
rect brew settings are programmed, the operator can
set the switch to the "DISABLE" position to prohibit
anyone from changing the settings.
BREW LOCKOUT
This function allows the operator to prevent or
allow brewing if the water temperature is less than
the set READY temperature.
To access this function screen press and hold the
® symbol. Release the ® when the display reads:
PROGRAM FUNCTIONS - LEVEL 1
The YES or NO should be flashing. Select YES to
prevent brewing if the water temperature is below the
set READY temperature. Select NO to permit brewing
at any water temperature.
When finished, press and release DONE. This
will exit this function screen and return to the MAIN
SCREEN on the display.
PROGRAMMING THE BREWER
The programming of the brewer is divided into two levels. There is one function in Level 1. All other functions
are accessed in Level 2.
The following function screens are in order of appearance. Each screen will have instructions on how to
access, and the procedures to program the various functions of the brewer.
IMPORTANT PROGRAMMING NOTES
- READ CAREFULLY -
To exit the programming mode at any time, press and release the ON/OFF switch (either on DUAL brewers)
located on the front switch panel. The display will return to the MAIN SCREEN.
If none of the five programming switches are pressed within one minute during the setup of the brewer,
the programming of the function screen that is being set will be exited and the display will return to the MAIN
SCREEN.
Always remember to place a container and funnel under the sprayhead when operating the brewer during the
set-up of PULSE BREW, CALIBRATE FLOW and testing the brew and bypass valves in SERVICE TOOLS/TEST
OUTPUTS.
PROGRAM
ENABLE
DISABLE
PROGRAMMING
SWITCH
P2424
READY TO BREW
WATER TEMP: 205°
Press here
for NO
Press here
for DONE
Press here
for YES
BREW LOCKOUT?
NO DONE YES