Page 22
27479 121500
To increase a brew volume, place the ON/OFF
switch in the "ON" position, press and hold the START
switch until three clicks are heard. Release the switch
and press it again one or more times. (Failure to re-
lease the switch within two seconds after the third
click causes the volume setting to be aborted and pre-
vious volume setting will remain in memory.) Each
time the switch is pressed, two seconds are added to
the brew time period. Allow the brew cycle to finish in
order to verify that the desired volume has been
achieved.
To decrease a brew volume, place the ON/OFF
switch in the "ON" position, press and release the
START switch once for every two-second interval to
be removed from the total brew time period; then im-
mediately press and hold down the START switch until
three clicks are heard. Release the switch. (Failure to
release the switch within two seconds after the third
click causes the volume setting to be aborted and pre-
vious volume setting will remain in memory). Allow
the brew cycle to finish in order to verify that the de-
sired volume has been achieved.
2. Setting brew volumes. To set a brew volume,
first check that the SET/LOCK switch is in the "SET"
position on the circuit board. Place the ON/OFF switch
in the "ON" position, press and hold the START switch
until three distinct clicks are heard and then release
the switch. (Failure to release the switch within two
seconds after the third click causes the volume set-
ting to be aborted and previous volume setting will
remain in memory.)
View the level of the liquid being dispensed. When
the desired level is reached, turn the ON/OFF switch
to "OFF".
NOTE: Several ounces of water will continue to sy-
phon from the tank after turning the switch "OFF". The
brewer remembers this volume and will continue to
brew batches of this size until the volume setting pro-
cedure is repeated.
NOTE: When brewing coffee, volume will decrease due
to absorption by the coffee grounds.
3. Setting programming disable feature. If it be-
comes necessary to prevent anyone from changing
brew time once programmed, you can set the SET/
LOCK switch to the "LOCK" position. This will prevent
any further programming until switch is once again
put into the "SET" position.
TL1 - WHI/RED to ON/OFF Switch and Solenoid
TL2 - WHI to Terminal Block (White insert on
102V, 120/208V or 120/240V Models)
WHI to Power Cord on 120V Model 15
RED to Terminal Block (Red insert on 200V
or 240V Models)
TL3 - WHI/ORN to Start Switch
TL4 - WHI/GRN to Solenoid
TL5 - WHI/YEL to Start Switch
FIG. 17 DIGITAL TIMER WIRING
P2037
SERVICE (cont.)
DIGITAL TIMER (Late Models)(cont.)