Bunn H5E Coffeemaker User Manual


 
5
TROUBLESHOOTING (cont.)
Problem Probable Cause Remedy
Equipment will not operate
(cont.)
Automatic refi ll will not oper-
ate after drawing hot water.
Water fl ows into the tank con-
tinuously (Dispenser discon-
nected from power source).
Water fl ows into the tank con-
tinuously (Dispenser connect-
ed to power source).
Water is cold.
2. Safety overfl ow switch
1. No water
2. Water strainer/fl ow control
3. Liquid level system
4. Solenoid valve
1. Solenoid valve
1. Liquid level system
1. Safety overfl ow switch
2. Limit thermostat
3. Tank heater
4. Temperature control
Refer to Service – safety overfl ow switch
for testing procedures.
Check plumbing and shut-off valves.
(A) Direction of fl ow arrow must be point-
ing towards dispenser.
(B) Remove the strainer/fl ow control and
check for obstructions. Clear or replace.
Refer to Service – electronic controls for
testing procedures.
Refer to Service – solenoid valve for test-
ing procedures.
Refer to Service – solenoid valve for test-
ing procedures.
Refer to Service – electronic controls for
testing procedures.
Refer to Service – safety overfl ow switch
for testing procedures.
Refer to Service – limit thermostat for
testing procedures.
Refer to Service – tank heater for testing
procedures.
Refer to Service – electronic controls for
testing procedures.
CAUTION – Do not eliminate or bypass limit thermostat. Use only B.O.M. replacement part #23717.0003.
42311 071310