13
SERVICE (cont.)
Safety Overfl ow Switch
Location:
The safety overfl ow switch is located inside the rear of
the dispenser inside the copper overfl ow cup.
For testing or removal of the safety overfl ow switch,
access may also be needed by removing the two screws
attaching the electronic control assembly to its mount-
ing bracket.
Test Procedure:
1. Once voltage is verifi ed at the power source, check
for continuity across the safety overfl ow switch
red wires only until the plastic fl oat is raised and
check that continuity returns when the plastic fl oat
is again lowered.
If continuity is present as described, reconnect each
of the red wires to the black wires, the safety overfl ow
switch is operating properly.
If continuity is not present as described, replace the
safety overfl ow switch.
FIG. 13a SAFETY OVERFLOW SWITCH
FIG. 13c SAFETY OVERFLOW WIRING
RED to BLK Wire from
Terminal Block
RED to BLK Wire from Elec-
tronic Control #3
P4093
P1777
Removal and Replacement:
1. Disconnect the black wires from the safety overfl ow
switch.
2. Remove the nut beneath the copper overfl ow cup.
3. Remove the entire switch assembly from the cup.
4. Place the new switch assembly into the cup, wires
fi rst. Make sure that a gasket is in place around the
threaded switch stem.
NOTE - The magnets must be at the top of the fl oat and
there must be NO stainless steel washers installed for
the safety overfl ow switch to operate properly.
5. Install the nut beneath the copper overfl ow cup.
Be sure not to overtighten.
6. Reconnect the wires, FIG. 6.
P1993
FIG. 13b OVERFLOW PROTECTION SWITCH
42311 071310
H 10
H 5