PROGRAMMING
When power is applied to the dispenser, the display located on the bottom of the main circuit board will show
the revision level of the software for 5 seconds, and then go to (-). While the tank is filling, the display will read
(FIL). When the tank is full the display will return to (-).
LEVEL 1 PROGRAMMING
TANK WATER TEMPERATURE & READY TEMPERATURE SET-UP
1. Press and hold the center button until P1 appears on the display (approximately 3
seconds) then release button. The tank water temperature set point will appear on
the display. Factory default is 200° F for most dispensers, and 90° F for some.
2. Press the (+) button to increase the temperature set point, and the (-) button to
decrease the set point.
3. After the Tank Temperature is entered, press and release the center button once
more. The display will read P2, then show the ready temperature set point. Factory
default is 195° F for most dispensers, and 85° F for some.
4. Use the (+) button to increase the temperature set point, and the (-) button to de-
crease the set point.
5. To exit Level 1 Program press and release the center button once more. The display
will show Software version, then (-).
LEVEL 2 PROGRAMMING
DISPENSE TEMPERATURE LOCKOUT, FAHRENHEIT OR CENTIGRADE SELECTION, &
FACTORY DEFAULTS
1. To enter Level 2 Programming, press and hold the center button until H1 appears
on the display (approximately 6 seconds) then release button. The display will either
read noL (LOCKOUT DISABLED) or Loc (LOCKOUT ENABLED). When (ENABLED),
unit will not dispense if the Tank Temperature is below the (READY) temperature
setting.
2. Use the (+) or (-) buttons to alternate between Loc and noL.
39338 012609