7
Faceplate Removal - H5 ELEMENT: After removing
top cover, remove the two upper screws securing the
faceplate. Carefully lift faceplate straight up until the
three lower screws clear the key holes.
The check valve, electronic control assembly, safety
overfl ow switch, solenoid valve, overfl ow tube tempera-
ture sensor and terminal block are located at the rear of
the dispenser. Access is gained by removing the upper
and lower rear panels. The upper is attached with six
8-32 slotted-head screws. The lower is attached with
four 8-32 slotted-head screws. The middle panel must
not be removed from the dispenser.
P1770.30
42311 022311
:$51,1*
9HU\+RW:DWHU
8VH:LWK&DUH
The check valve, electronic control assembly, over-
fl ow protection switch, solenoid valve, overfl ow tube
temperature sensor, triac assembly (EARLY MODELS
ONLY) and terminal block are located on the side of
the dispenser. Access is gained by removing the side
panel. The panel is attached with eight 8-32 slotted-
head screws.
P878.30
SERVICE
WARNING – Disconnect the dispenser from the power source before the removal of any panel or the replacement
of any component. WARNING - Inspection, testing, and repair of electrical equipment should be performed only
by qualifi ed service personnel. Disconnect the dispenser fromthe power source when servicing, except when
electrical tests are required and the test procedure specifi cally states to connect the dispenser to the power source.
Component Access - H5E/DV-PC/X Component Access - H10X