Bunn JDF-2 Beverage Dispenser User Manual


 
4
PLUMBING REQUIREMENTS
This dispenser must be connected to a COLD WATER system with operating pressure between 20 and 100 psi
(138 and 690 kPa). This water source must be capable of producing a minimum flow rate of 3 fluid ounces (88.7
milliliters) per second. A shut off valve should be installed in the line before the dispenser. Install a regulator in
the line when pressure is greater than 100 psi (690 kPa) to reduce it to 50 psi (345 kPa). The main water inlet is
a 3/8” (9.52 mm) MFL connection.
Additionally, the dispenser’s rinse connection may be connected to a HOT WATER system.
Caution:
MAXIMUM RINSE WATER TEMPERATURE: 170 degrees F (76.6 degrees C)
Use BUNN-O-MATIC tubing, part number 32759.10_ _ (see Illustrated Parts Catalog for complete part number)
for hot water connection.
The rinse water operating pressure must be between 20 and 100 psi (138 and 690 kPa). A shut off valve should
be installed in the line before the dispenser. Install a regulator in the line when pressure is greater than 100 psi (690
kPa) to reduce it to 50 psi (345 kPa). The rinse water inlet is a 1/4" (6.35 mm) MFL connection.
NOTE- At least 18 inches (457 mm) of an FDA approved flexible beverage tubing, such as reinforced braided
polyethylene or silicone, before the dispenser will facilitate movement to clean the countertop. It can be pur-
chased direct from BUNN-O-MATIC (part number 32759.10_ _ [see Illustrated Parts Catalog for complete part
INITIAL SET-UP
CAUTION: The dispenser is very heavy! Use care when lifting or moving it. Use at least two people to lift or move
the dispenser. Place dispenser on a sturdy counter or shelf able to support at least 150 lbs. (68 kg). The JDF-2
is designed for indoor use only.
Set the dispenser on the counter where it will be used. The JDF-2 requires a minimum of 4 inches (102 mm)
of air clearance at the rear and 8 inches (203 mm) of air clearance above the dispenser. Minimal clearance is
required between the dispenser sides and the wall or another appliance. For optimum performance,
do not let warm
air from surrounding machines blow on the JDF-2. Leave some space so the dispenser can be moved for cleaning.
ELECTRICAL REQUIREMENTS
CAUTION: The dispenser must be disconnected from the power source until specified in
Electrical Hook-Up
.
The 120V rated dispensers have an attached cord set and require a 2-wire, grounded, individual branch circuit
rated 120 volts ac, 15 amp, single phase, 60Hz. The mating connector must be a NEMA 5-15R. (Refer to the data
plate for exact electrical requirements.)
The 230V rated dispensers have an attached cord that requires an attachment plug cap rated at least 10a, 230V.
The attachment plug cap must meet with applicable national/local electrical codes.
ELECTRICAL HOOK-UP
CAUTION: Improper electrical installation will damage electronic components.
1. An electrician must provide electrical service as specified.
2. Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.
3. Connect the dispenser to the power source.
4. If plumbing is to be hooked up later, be sure the dispenser is disconnected from the power source. If plumbing
has been hooked up, the dispenser is ready for
Initial Fill
.
35303 081503