12
CLEANING (cont)
6. Select the dispense stations by pressing the “Dispense Switch” for that station. Use the “+/Stop Switch” for
portion contol dispensers. The “REFILL” indicator will light and the beeper will sound for the dispense head
selected.
7. Once the dispense heads have been selected, press and hold the “Sanitize Switch” for 5 seconds again to initiate
the automatic cycle. (When the cycle is initiated the “SANITIZE” indicator lights steadily and the “REFILL”
indicator for each station being sanitized will flash.)
Note: The sanitize routine takes 8 minutes. During the sanitize routine the following steps will occur in sequence:
A) The pumps at the selected dispense heads will run for 1 minute, or until the bottles filled
with hot water empty, whichever occurs first.
B) The dispenser will sit idle for 5 minutes.
C) The pumps at the selected dispense heads will run for 2 minutes or until the bottles filled
with hot water empty, whichever occurs first.
D) The beeper will sound once every 3 seconds to indicate completion of the sanitize
routine.
Note: To terminate a sanitize program mid-cycle, momentarily press and release the “Sanitize Switch” and proceed
to step 17. The sanitize program should be restarted from step 1 to ensure proper sanitization.
8. Once the cycle is completed, disconnect the sanitizing hose(s) from the nozzle(s) and empty the bucket.
9. Remove each dispense nozzle and mixing element and run under hot tap water to remove excess pulp.
10. Prepare 2.5 gal. (9.46 L) of sanitizing solution by dissolving 1 packet of Kay 5 sanitizer into 2.5 gal. (9.46 L)
of 120°F (48.9°C) water to ensure 100 ppm of available chlorine.
11. Place nozzle(s) and mixing element(s) in a separate 1 quart container of sanitizing solution and mix thoroughly.
Allow the part to soak for 2 minutes.
12. Clean the dispense nozzle receptacle(s) (dispense valves) with the sanitizing solution and a soft bristle brush.
13. Clean the concentrate bottle’s inlet adapter(s) using the sanitizing solution and a soft bristle brush.
14. Replace the mixing element(s) and nozzle(s), reattach the sanitizing hose(s) to the nozzle(s), and insert the
hoses into the catch bucket.
15. Fill approximately 64 ounces (1.89 L) of clean sanitizing solution into clean, empty concentrate container(s).
Do not use the sanitizing solution used in step 11. Load the containers into the dispenser.
16. Repeat steps 5 through 8.
Note: The sanitize routine takes 8 minutes. During the sanitize routine the following steps will occur in sequence:
A) The pumps at the selected dispense heads will run for 1 minute, or until the bottles filled
with sanitizing solution empty, whichever occurs first.
B) The dispenser will sit idle for 5 minutes.
C) The pumps at the selected dispense heads will run for 2 minutes or until the bottles filled
with sanitizing solution empty, whichever occurs first.
D) The beeper will sound once every 3 seconds to indicate completion of the sanitize
routine.
17. Replace the sanitizing solution with concentrate and reattach the drip tray.
18. Activate a rinse cycle at each station as described in DAILY RINSE PROCEDURE.
19. At each station, actuate the Dispense Switch until juice appears. Then pour one 12 ounce (354.9 ml) glass of
juice and discard.
20. Wipe internal and external surfaces with a clean, damp cloth.
33854 092101