OPERATING CONTROLS AND INTERFACE
1. Dispense Switches: Pull and Hold to dispense product.
2. Stop Switch: Momentary switch stops all dispense functions.
3. Alternate Portion Control Switch: Momentarily pushed to select the Alternate Portion Control Volume.
4. Function Selector Switch: Allows the user to set the dispenser into different dispensing modes.
a. Rinse: Dispenses water only- Flushes the mix chamber and dispense tip.
b. Prime: Dispenses concentrates only – Primes the concentrate pump.
c. Normal: Normal dispense mode - Dispenses mixed product (concentrate and water).
5. Mode Selector Switch: Allows the user to set the dispenser into different operating modes.
a. Run: Normal operating position.
b. Off: Turns off all functions.
WARNING - The OFF Mode does not remove AC power from the dispenser. Disconnect power source before
servicing the dispenser
c. Night: Anti-pilfering mode that disables dispensing.
6. Door Interlock Switch: Unit will not dispense product if the door is open.
7. Power LED: Red - illuminates when AC power is applied to dispenser.
8. Portion LED: Yellow - illuminates when the portion dispense option has been selected, (5 second delay).
9. Rinse LED: Yellow - illuminates when the optional preset rinse alarm time has elapsed.
10. Left Refill LED: Yellow - illuminates when the Left Concentrate BIB needs replaced.
11. Right Refill LED: Yellow - illuminates when the Right Concentrate BIB needs replaced.
12. Programming Keypad: Used in conjunction with the LCD display to program and calibrate the dispenser to
customer specific requirements. (Located behind the splash guard panel)
13. LCD Display: Displays programming menus and fault messages. (Located behind the splash guard panel)
BUNN ICED COFFEE
AMBIENT UNIT
7
8
9
11
2
6
10
13
12
1
3
4 5