Bunn LCC-2 Coffeemaker User Manual


 
18
MENU SCREEN ACTION DESCRIPTION
CAL RIGHT PUMP ?
PULL DISPENSER
CAL RT PUMP VOL
(-) 43mL (+)
CAL RT WTR FLOW
PULL DISPENSER
CAL RT WTR VOL
(-) 36.0OZ (+)
CAL RIGHT SIDE ?
EXIT YES
CAL HOT WTR FLO ?
PULL DISPENSE
CAL HOT WTR VOL
(-) 34.0OZ (+)
XXX CAL -> XXX
(-) TankTemp (+)
Place a 50 mL (#34843.1000)
graduated cylinder under
the Right dispense tip, then
activate the Right Dispenser
Use the (+) or (-) buttons to
enter volume collected
Place a 64 Oz. (2000 mL)
container under the Right
dispense tip, then activate the
Right Dispenser
Use the (+) or (-) buttons to
enter volume collected
NONE
Place a 64 Oz. (2000 mL)
container under the Hot Water
dispense tip, then activate the
Hot Water Dispenser
Use the (+) or (-) buttons to
enter volume collected
Use the (+) or (-) buttons to
adjust temperature reading
The Right Pump will dispense concentrate for
20 seconds, then shut off automatically. Collect
and measure the concentrate dispensed.
Enter the volume of concentrate measured from
the Right Pump in mL(not Oz.) regardless of
Preferred Units selected.
The Right Dispenser will dispense hot water for
20 seconds, then shut off automatically. Collect
and measure the water dispensed.
Enter the volume of the water measured from the
Right dispenser in Oz. (mL)
Scroll down to bypass this screen.
The Hot Water Dispenser will dispense for 20
seconds, then shut off automatically. Collect and
measure the water dispensed.
Enter the volume of the water measured from the
Hot Water Dispenser in Oz. (mL)
Adjust the display reading to match a calibrated
probe inserted next to the Tank Sensor, °F (°C).
34766.1 010313
If NO - skip to next menu.
Used to set the maximum adjustment the Flavor
Guard feature is allowed to make, [3 - 15%].
Displays the Left Dispenser target RPM and
Conductance Reading, (Diagnostics Only)
Displays the Right Dispenser target RPM and
Conductance Reading, (Diagnostics Only)
Use the (+) or (-) buttons to
adjust % value
NONE
NONE
FlvrGrdRange 10%
(-) EXIT (+)
LfFlvrGrdTargets
RPM XXX-CON XXX
RtFlvrGrdTargets
RPM XXX-CON XXX
For Portion Control Dispensers (LCA-2 PC, LCA-2C PC, LCA-2A PC) only