Page 19
To increase a brew volume, place the ON/OFF
switch in the "ON" position, press and hold the START
switch until three clicks are heard. Release the switch
and press it again one or more times. (Failure to re-
lease the switch within two seconds after the third click
causes the volume setting to be aborted and previous
volume setting will remain in memory.) Each time the
switch is pressed, two seconds are added to the brew
time period. Allow the brew cycle to fi nish in order to
verify that the desired volume has been achieved.
To decrease a brew volume, place the ON/OFF
switch in the "ON" position, press and release the
START switch once for every two-second interval to
be removed from the total brew time period; then im-
mediately press and hold down the START switch until
three clicks are heard. Release the switch. (Failure to
release the switch within two seconds after the third
click causes the volume setting to be aborted and
previous volume setting will remain in memory). Al-
low the brew cycle to fi nish in order to verify that the
desired volume has been achieved.
2. Setting brew volumes. To set a brew volume,
fi rst check that the SET/LOCK switch is in the "SET"
position on the circuit board. Place the ON/OFF switch
in the "ON" position, press and hold the START switch
until three distinct clicks are heard and then release
the switch. (Failure to release the switch within two
seconds after the third click causes the volume setting
to be aborted and previous volume setting will remain
in memory.)
View the level of the liquid being dispensed. When
the desired level is reached, turn the ON/OFF switch
to "OFF".
NOTE: Several ounces of water will continue to sy-
phon from the tank after turning the switch "OFF".
The brewer remembers this volume and will continue
to brew batches of this size until the volume setting
procedure is repeated.
NOTE: When brewing tea, volume will decrease due
to absorption by the tea grounds.
3. Setting programming disable feature. If it be-
comes necessary to prevent anyone from changing
brew time once programmed, you can set the SET/
LOCK switch to the "LOCK" position. This will prevent
any further programming until switch is once again
put into the "SET" position.
SERVICE (cont.)
DIGITAL BREW TIMER (cont.)
TL1 - WHI/VIO to Dilution Timer and
WHI/VIO to ON/OFF Switch
TL2 - WHI to Power Cord (100V & 120V) or
RED to Power connector (230V) and
WHI to Dilution Timer (100V & 120V) or
RED to Dilution Timer (230V)
TL3 - WHI/ORN to Start Switch
TL4 - WHI/GRN to Brew Solenoid
TL5 - WHI/YEL to Start Switch
FIG. 7 DIGITAL TIMER WIRING
P2037
37235 080204