INITIAL SET-UP
CAUTION - The brewer must be disconnected from the power source throughout the initial set-up, except when
specifi ed in the instructions.
1. Remove the top lid from the brewer.
2. Rotate the control thermostat knob fully counterclockwise to the "OFF" position and replace the top lid.
3. Set the delay knob of the timer on the right side of the hood at eight minutes and the dilution knob of the
timer on the right side of the hood at three minutes and forty-fi ve seconds.
4. Remove the metal discharge tip from the funnel to speed up the set-up procedure. Insert the empty funnel
into the funnel rails.
5. Place an empty dispenser on the brewer base. Be sure the funnel discharge is directly above the hole in the
dispenser top lid.
6. Plug in the brewer and place the ON/OFF switch in the "ON" position. Momentarily press the start switch.
Water will fl ow into the tank and will shut off after three minutes. Press the start switch again. During the
second period, the tank will fi ll to its capacity and the excess will fl ow from the funnel into the dispenser.
7. Place the ON/OFF switch in the "OFF" position.
8. Disconnect the brewer from the power source and remove the top lid.