Bunn TB3-LP Hot Beverage Maker User Manual


 
Page 6
INITIAL SET-UP (TB3Q/TB3Q-LP/TB6Q ONLY)
CAUTION - The brewer must be disconnected from the power source throughout the Initial Set-Up, except
when specified in the instructions.
1. Remove the top cover from the brewer.
2. Rotate the control thermostat knob fully counterclockwise to the "OFF" position and replace the top lid.
3. Insert an empty funnel into the funnel rails. On TB6Q models, rotate the funnel handle left or right to align
the funnel discharge over the reservoir.
4. Place an empty dispenser on the brewer base. Be prepared to empty the dispenser during these initial steps.
Be sure funnel discharge is directly above the dispenser.
5. Plug in the brewer, place the ON/OFF switch in the "ON" position ("SWEET" or "UNSWEET" position for models
with a sweetener option) (LEFT or RIGHT on TB6Q), and momentarily press the START switch. Water will
flow into the tank and dispenser for three and one-half minutes. Empty the dispenser when this first cycle
stops and press the START switch again. Empty the dispenser when the second cycle stops and press the
START switch once more. During the third cycle, the tank will fill to its capacity and the excess will flow
from the funnel into the dispenser. Empty the dispenser when this third cycle stops.
6. Begin another brew cycle and measure the total water volume from the dispenser. It should be approximately
3 gallons and 12 ounces. (396 ounces). CONCENTRATE MACHINES WILL YIELD ONLY 76 OZ.
7. If not, adjust the timer as required. See Adjusting Brew Volumes.
8. Unplug the brewer, remove the top lid, rotate the control thermostat knob fully clockwise to the "ON" position
and replace the top lid.
9. Empty the dispenser.
10. Plug in the brewer and wait for the water in the tank to heat to brewing temperature (approximately 20
minutes). Some water will drip from the funnel during this time; this is due to expansion and should not
occur thereafter.
11. Begin another brew cycle. Empty the reservoir after water has stopped flowing from the funnel.
41465.1 040609
-1000 213.8 101.0 200 93.3
-500 212.9 100.5 200 93.3
0 212.0 100.0 200 93.3
500 211.1 99.5 200 93.3
1000 210.2 99.0 200 93.3
1500 209.3 98.5 200 93.3
2000 208.4 98.0 200 93.3
2500 207.4 97.4 200 93.3
3000 206.5 96.9 199 92.8
3500 205.6 96.4 198 92.2
4000 204.7 95.9 197 91.7
4500 203.8 95.4 196 91.1
5000 202.9 94.9 195 90.6
5500 201.9 94.4 195 90.6
6000 201.0 93.9 194 90.0
6500 200.1 93.4 193 89.4
7000 199.2 92.9 192 88.9
7500 198.3 92.4 191 88.3
8000 197.4 91.9 190 87.8
8500 196.5 91.4 189 87.2
9000 195.5 90.8 188 86.7
9500 194.6 90.3 187 86.1
10000 193.7 89.8 186 85.6
Brew water temperature is factory set at 205° F (96.1° C)
Areas of high altitude will require lowering this tempera-
ture to prevent boiling. This chart should be used as a
guide when readjusting the brew water temperature.
Altitude
(Feet)
Boiling point
of water
° F ° C
Recommended
water temperature
° F ° C
12. Allow the water in the tank to heat to the proper tem-
perature.
13. The brewer is now ready to brew approximately 3
gallons of freshly brewed room temperature tea from
three to five ounces of loose leaves.