Bunn TB3Q Ice Tea Maker User Manual


 
Page 11
TROUBLESHOOTING (cont.)
PROBLEM
PROBABLE CAUSE
REMEDY
Brew cycle will not start (cont.)
Water is not hot
Dilution cycle will not start
Inconsistent beverage level in
dispenser
6. Brew Timer
7. Brew Solenoid Valve
1. Limit Thermostat
CAUTION - Do not eliminate or by-
pass limit thermostat or thermal
cut-off. Use only BOM replacement
part #29329.0001
2. Control Thermostat
3. Tank Heater
1. ON/OFF
2. Start Switch
1. Syphon System
2. Lime Build-up
CAUTION - Tank and tank compo-
nents should be delimed regularly
depending on local water condi-
tions. Excessive mineral build-up
on stainless steel surfaces can ini-
tiate corrosive reactions resulting
in serious leaks.
3. Water Pressure
Refer to
Service
- Brew Timer for
testing procedures. See page 17
Refer to
Service
- Brew Solenoid
Valve for testing procedures. See
page 16
Refer to
Service
- Limit Thermostat
for testing procedures. See page
20.
Refer to
Service
- Control Thermo-
stat for testing procedures. See
page 19
Refer to
Service
- Tank Heater for
testing procedures. See page 25
Refer to
Service
- ON/OFF Switch
for testing. See page 21
Refer to
Service
- Start Switch for
testing procedures. See page 22.
The brewer must be level or slightly
lower in front to syphon properly
Inspect the tank assembly for ex-
cessive lime deposits. Delime as
required.
The water pressure to the brewer
must be at least 20 psi (138 kPa).
37236 050305