Page 6
37236 050305
AUTO SWEETENER SET-UP
CAUTION - The brewer must be disconnected from the power source throughout the Initial Set-Up, except
when specified in the instructions.
1. Remove the top lid and both rear panels.
2. Make sure the brewer water supply is off.
3. Connect sweetener hose from the bag in a box delivery system to the rear fitting marked "Sweetener" .
IMPORTANT - System delivery pressure must be regulated between 30-40 psi. System also needs to deliver
product for at least 4 minutes without shutting off. Some pump systems shut off after a few minutes of continu-
ous running.
4. Plug brewer into the power source.
5. Place an empty reservoir under the dilution nozzle of the brewer.
6. Close the adjustment valve on the rear of the brewer fully (clockwise), then open (counterclockwise) 1/2
turn.
7. Set the selector switch to the "Sweetened" side and press the "Start" switch momentarily. (The sweetener will
come out immediately.)
8. Run sweetener for 1 minute, then set selector switch to the "Off" position. The flow will stop.
9. Measure the amount of sweetener dispensed and calculate if the volume needs to be increased or decreased
(Dilution cycle is usually between 3 to 3 1/2 minutes).
10. If adjustment is needed, turning the adjustment valve clockwise decreases the amount of sweetener dis-
pensed and turning the adjustment valve counterclockwise increases the amount of sweetener dispensed.
11. After the desired volume has been set, turn the water supply on.
12. Reinstall the top lid, lower and upper rear panels.
The brewer may now be returned to service.