The cooker is designed to match the depth of standard 600mm worktops. An adaptor
backplate should, therefore, be fitted within the shaded area shown to allow the
cooker to be pushed fully to the wall. If a forward facing backplate is used, it must be
chased into the wall.
Connection to the cooker should be made with an approved appliance flexible
connection to BS 669. LPG cookers should be connected with a hose suitable for LPG
and capable of withstanding 50 mbars pressure. A length of 0.9 to 1.25m is
recommended. The length of hose chosen should be such that when the cooker is in
situ, the hose does not touch the floor.
The temperature rise of areas at the rear of the cooker that are likely to come in
contact with the flexible hose do not exceed 70˚C.
22
CONNECTING TO GAS SUPPLY
180
460
490
250