6
c) Minimum regulation of the hob burners:
•
turn the tap to minimum;
• remove the knob and adjust the regulation screw, which is positioned in or next to the tap pin, until the
flame is small but steady.
N.B.: in the case of liquid gas, the regulation screw must be screwed in to the bottom.
• check that the flame does not turn off when you turn the tap quickly from high to low.
d) Regulating the primary air of the burners:
The primary air of the burners requires no regulation.
Adapting to different types of gas
In order to adapt the oven to a different type of gas with respect to the gas for which it was manufactured
(indicated on the label), follow these simple steps:
a) Replacing the oven burner nozzle
• open the oven door fully
• pull out the sliding oven bottom
V
V
Z
• Pry the fixing tab “V” and remove the oven burner
• Unscrew the oven burner nozzle using the socket spanner for the nozzles “Z”, or a 7 mm socket spanner,
and replace it with a nozzle suited to the new type of gas (see Table 1).
Take particular care handling the spark plug wires and the thermocouple pipes.
• Replace all the parts, following the steps described above in the reverse order.
b) Minimum regulation of the gas oven burner with thermostat:
• light the burner as described in the paragraph “the oven knob” of the instruction booklet.
• turn the knob to Max for about 10 minutes and then turn the knob to the Min setting;
• remove the knob;
• regulate the screw positioned outside the thermostat pin until the flame is small but steady.
N.B.: in the case of liquid gas, the regulation screw must be screwed in to the bottom.