Cannon C50GLX Cooktop User Manual


 
9
Burner and Nozzle Specifications
Table 1 Liquid Gas Natural Gas
Burner Diameter Thermal
Power
kW
(p.c.s.*)
Thermal
Power
kW
(p.c.s.*)
By-Pass
1/100
Nozzle
1/100
Flow*
g/h
Thermal
Power
kW
(p.c.s.*)
Nozzle
1/100
Flow*
l/h
(mm) Nominal Reduced (mm) (mm) *** ** Reduced (mm)
Fast
(Large)(R)
100 94 2,60 0,70 41 80 189 186 0,70 118 248
Semi Fast
(Medium)(S)
75 69 1,90 0,40 30 70 138 136 0,40 104 181
Auxiliary
(Small)(A)
51 46 1,00 0,40 30 52 73 71 0,40 76 95
Oven - 2,60 0,60 36 71 189 186 0,60 115 248
Grill - 2,50 1,30 63 80 182 179 1,30 122 238
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
* At 15°C and 1013 mbar- dry gas
** Propane P.C.S. = 50,37 MJ/Kg
*** Butane P.C.S. = 49,47 MJ/Kg
Natural P.C.S. = 37,78 MJ/m
3
S
S
R
A
C50GLB
C50GLK
C50GLW
C50GLS
C50GLX
C50LCIK
C50LCIW
C50GCIK
C50GCIW