Cannon C50HNB Cooktop User Manual


 
11
Burner and Nozzle Specifications
Table 1 Liquid Gas Natural Gas
Burner Diameter Thermal Power
kW (p.c.s.*)
Thermal Power
kW (p.c.s.*)
By-Pass
1/100
Nozzle
1/100
Flow*
g/h
Thermal Power
kW (p.c.s.*)
Nozzle
1/100
Flow*
l/h
(mm) Nominal Reduced (mm) (mm) *** ** Reduced (mm)
Fast
(Large)(R)
100 94 3,00 0,70 41 87 218 214 0,70 128 286
Semi Fast
(Medium)(S)
75 69 1,90 0,40 30 70 138 136 0,40 104 181
Auxiliary
(Small)(A)
51 46 1,00 0,40 30 52 73 71 0,40 76 95
Oven - 2,60 0,60 36 75 189 186 0,60 123 248
Grill - 3,60 2,40 90 94 262 257 1,40 140 343
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
* At 15°C and 1013 mbar- dry gas
** Propane P.C.S. = 50,37 MJ/Kg
*** Butane P.C.S. = 49,47 MJ/Kg
Natural P.C.S. = 37,78 MJ/m
3
S
S
R
A
C50HNW
C50HNB