Cannon C50HNB Cooktop User Manual


 
4
Installation
The appliance must only be installed by a competent person. In the UK, CORGI registered installers undertake
to work to safe and satisfactory standards.
Before moving your cooker check that it is cool, and switch off at the cooker control unit.
Splashplate optional, apply to Parts Department (see Back Cover for contact number.)
The following instructions should be read by a qualified technician to ensure that the appliance is installed, regulated
and technically serviced correctly in compliance with current regulations.
Important: remember to unplug the appliance from the mains before regulating the appliance or carrying out
any maintenance work.
Positioning
Important: this unit may be installed and used only in permanently ventilated rooms according to the British Standards
Codes Of Practice: B.S. 6172/B.S. 5440, Par. 2 and B.S. 6891 Current Editions. The following requirements must be
observed:
a) The cooker should not be installed in a bed sitting room with a volume of less than 20m
3
. If it is installed in a room of
volume less than 5m
3
an air vent of effective area of 110cm
2
is required, if it is installed in a room of volume between
5m
3
and 10m
3
a supplementary airvent area of 50cm2 is required, if the volume exceeds 11m
3
no airvent is required.
However, if the room has a door or a window which opens directly to the outside no air vent is required even when the
volume is between 5m
3
and 11m
3
.
b) During prolonged use of the appliance you may consider it necessary to open a window to the outside to improve
ventilation.
c) If there are other fuel burning appliances in the same room, B.S.5440 Part 2 Current Edition, should, be consulted to
determine the requisite air vent requirements.
Installation of the cooker
For a correct installation of the cooker the following precautions must be followed:
The height of the cooker can be adjusted by means of adjustable feet in the plinth (900mm - 930mm). Adjust the feet by
tilting the cooker from the side. Then install the product into position.
NOTE: This appliance must not be fitted on a platform.
The cooker is designed to fit between kitchen cabinets spaced 500mm apart. The space either side need only be sufficient
to allow withdrawal of the cooker for servicing. It can be used with cabinets one side or both as well as in a corner setting.
It can also be used free-standing.
Adjacent side walls which project above hob level, must not be nearer to the cooker than 125mm and should be protected
by heat resistant material. Any overhanging surface or cooker hood should not be nearer than 400mm. (Fig.A)
a) The cooker may be located in a kitchen, a kitchen/diner or bed sitting room, but not in a bathroom or shower room.
b) The hoods must be installed according to the requirements in the hood handbook.
c) The wall in contact with the back of the cooker must be of flameproof material.
d) The cooker is fitted with a safety chain that must be attached to a hook, secured to the wall behind the appliance.
125mm
Min
400mm
Min
503mm
Min
1450mm
1850mm
125mm
Min
Fig. A
Gas connection