ELECTRICAL CONNECTION
Warning - THIS APPLIANCE MUST BE EARTHED
The cooker must be connected by a qualified electrician to a suitable double - pole
control unit with a minimum rating of 32A and a minimum contact clearance of 3mm,
which should be fitted adjacent to (but not above) the cooker, in accordance with IEE
regulations.
The power supply cable should conform to BS6004 with a conductor size of 4mm
2
.
The control unit should be easily accessible in the event of an emergency.
This appliance conforms to EN55014 regarding suppression of radio and television
interference.
Access to the mains terminals is gained by removing the rear access cover.
The mains cable must pass through the cable clamp and the screws must be fully
tightened. Sufficient cable should be used to allow the cooker to be pulled out for
servicing. Ensure that the cover is fully closed and secure afterwards.
Take care not to trap the mains cable when pushing the cooker into its final position.