27
AUTOMATIC CHANGEOVER WITH COMPLETE C CONTROLLER
COMPLETE
C
CONTROL
UMT
BR1
BR2
PBS
CR
CAP
PB
GROUND
TRANSFORMER
RED
3
4
BRN
YEL
YEL
YEL
RED
6A
5A
RED
5
RED
RED
PBS
RED
RED
ORG
BRN
YEL
5
3A
UMT
2
3
1
6
7A
BRN
7
YEL
YEL
ORG
6
DM
ORG
RED
BRN
BRN
BRN
YEL
BR1
BR2
BLU
WV
SEE
NOTE 7
BR BRG CCG
R
Y
Y
W
O
G
R
C
AL1
AL2
A
P1
ALARM
RELAY
C
SEE
NOTE 6
JW1
JW3
FP1
JW2
FP2
SEE
NOTE 4
TEST PINS
SEE
NOTE 7
YELBRN
CC
YEL
COMPR.
RELAY
STATUS
LED
G
COMPLETE C
MICRO-
PROCESSOR
CONTROL
LOGIC
HP
LOC
FP1
FP2
RV
CO12
P2
24V
DC
EH1
EH2
P3
CO
1
2
3
4
5
6
7
8
9
10
10
HP
LOC
FP1
FP2
RVS
CO
SEE
NOTE 4
RED
RED
BLU
BRN
GRY
GRY
VIO
VIO
BRN
ORG
NOT USED
DIP SWITCH
OFF ON
PM: DISABLED/
ENABLED
STAGE 2: 2/1
NOT USED
NOT USED
FP1/FP2
FAULTS: 3/1
1
2
3
4
5
BLK
ORG
230V
24V
TRANS
CB*
POWER SUPPLY
REFER TO DATA PLATE
USE COPPER CONDUCTORS ONLY.
SEE NOTE 2
REFER TO DISCONNECT
BOX FOR OPTIONAL
POWER SUPPLY CONNECTION
GROUND
L2
L1
OPTIONAL
CORD
CONNECTION
RED
NEUTRAL ON 265V
SYSTEMS
L2 (ribbed)
GROUND
L1 (plain)
PB
1
2
H
C
F
CAP
RED
RED
6
8
2
4
BLK
BLK
R
S
C
CR
BLU
COMPRESSOR
BRN
YEL
BLK
BLK
BLK
2
1
5
6
7
BM
B (HIGH)
A(LOW)
RED
RED
BLK
PBS
7A
6A
5A
115
208
230
265
WHT
RED
ORG
BRN
LEAD COLOR
VOLTAGE
TRANSFORMER PRIMARY
LEAD COLORS
SEE
NOTE 3
PUSH BUTTON SWITCH ATTRIBUTES
X = CLOSED O = OPEN
TERMINALS 1 2345678
1A 1B 2A 3A 4A 5A 6A 7A 8A
STOP XOOOOOOOO
FAN ONLY XOOOOXOOO
LOW FAN XOOXXOXOO
HIGH FAN XOOXXOOXX
BLOWER MOTOR WIRING
UNIT SIZE POLE A POLE B
07 5 3
09 5 4
12 4 3
15 4 3
19 4 3
AL — Alarm Relay Contacts
BM — Blower Motor
BR — Blower Relay
CAP — Capacitor
CB — Circuit Breaker
CO — Sensor, Condensate Overflow
CR — Compressor Relay
DM — Damper Motor
FP1 — Sensor, Water Coil Freeze Protection
FP2 — Sensor, Air Coil Freeze Protection
HP — High-Pressure Switch
JW1 — Jumper Wire for Alarm
LOC — Loss of Charge Pressure Switch
PB — Power Terminal Block
PBS — Push Button Switch
PM — Performance Monitor
RVS — Reversing Valve Solenoid
TRANS — Transformer
UMT — Unit Mounted Thermostat
WV — Water Valve
---------- Field Line Voltage Wiring
Field Low-Voltage Wiring
*Optional wiring.
NOTES:
1. Compressor and blower motor thermally pro-
tected internally.
2. All wiring to the unit must comply with local
codes.
3. Transformer is wired to 115-V (WHT) lead for
115/1/60 units, 265-V (BRN) lead for 265/1/60
units or 208-V (RED) lead for 208/1/60 units.
For 203/1/60 switch RED and ORG leads at L1
and insulate RED lead.
Transformer is energy limiting or may have cir-
cuit breaker.
4. FP1 thermistor provides freeze protection for
WATER. When using ANTI-FREEZE solutions,
cut JW3 jumper.
5. Typical unit-mounted thermostat wiring shown.
6. 24-V alarm signal shown. For dry alarm con-
tact, cut JW1 jumper and dry contact will be
available between AL1 and AL2.
7. Transformer secondary ground via Complete
C board standoffs and screws to control box.
(Ground available from top two standoffs as
shown.)
LEGEND
Printed Circuit Trace
Relay/Contactor Coil
Solenoid Coil
Thermistor
Circuit Breaker
Relay Contacts-N.O.
Switch-Temperature
Switch-High Pressure
Switch-Low Pressure
Ground
Wire Nut
Mate-N-Lock
>
>