Installation
IMPORTANT:
The extractor is intended to be mounted to the ceiling
using fixings appropriate for the ceiling. Ensure that
there is adequate ceiling strength and supports at the
fixing points; if in doubt, consult a joiner or electrician.
INSTALLATION:
The extractor is intended to be operated as a re-circulation
device suspended from the ceiling, as shown in Fig 11.
When installing this appliance over a CDA hob, the clearance
between the extractor and the hob must be equal to or exceed
650mm. This instruction overrides the instructions supplied
with the CDA hob. (The height should be measured from the
top of the hotplates or burners)
Where the extractor is to be installed above a non-CDA hob,
the instructions supplied with the hob may dictate that the
height required above the hob is greater than 650mm.
IN THE ABSENCE OF ANY INSTRUCTIONS SUPPLIED
WITH THE HOB, THE MINIMUM DISTANCE BETWEEN
THE HOB AND EXTRACTOR MUST BE AT LEAST 760mm
Mounting The Extractor
1. Using the supplied template, mark the positions of the 3
main fixing holes (E) and the 2 additional fixing holes (X)
on the ceiling.
2. Drill and plug the holes, as required. If screwing
directly to the ceiling joists, plugs may not be required
(See Important note above)
3. Insert 3 screws (E) into the main fixings, leaving
approximately 3mm protruding, as shown in Fig 12.
Fig. 11
650mm
Fig. 12
min 3mm
E
E
E
E