Mounting The Extractor
7. Loosen the body fixing screws (G in Fig 16) by
approximately 3mm and hook the cable fixing bracket into
place. Lift the bracket into position and tighten the screw to
lock the bracket in position, then insert an additional screw
(H) for security.
8. Make any adjustments to the cable length, ensuring that the
extractor is level. Using 2 x 8mm spanners, the extractor can
be levelled using the adjustment system Fig. 17
9. Mount the mains connection box (S) to the ceiling support
plate using the 2 supplied screws (D) and proceed to
connect the appliance to the mains supply, as shown below.
Once complete, secure the connection box lid with the
2 screws. If you are in doubt as to how to connect the
appliance to the mains supply consult a qualified electrician.
Fig. 17
Fig. 16
Fig. 18
F
G
2/3mm
G
H
H
B
C
F
1 2 3
2
1
R
D
D
1
D
2
S
3
4
E
4
1