CDA CIN6 Ventilation Hood User Manual


 
Installation
When the extractor is to be installed above an electric hob, the minimum distance between the hob and extractor must exceed
600mm (650mm is recommended).
When the extractor is to be installed above a gas hob, the minimum distance between the hob and extractor must exceed
700mm (750mm is recommended).
If the instructions provided with your gas hob state that the required distance between the hob and extractor must be greater
than 700mm, then that is the distance that should be observed; this is a legal requirement and may lead to your hob being
disconnected from the gas supply and the installation being reported to RIDDOR (The height should be measured from the top
of the burners).
IN THE ABSENCE OF ANY INSTRUCTIONS SUPPLIED WITH THE GAS HOB, THE MINIMUM DISTANCE BETWEEN
THE HOB AND EXTRACTOR MUST BE AT LEAST 760mm.
The width of any hob must not be greater than the width of the extractor installed above it.
Fig. 3
Gas: 750mm recommended
Electric: 650mm recommended