CDA HCG 730 Cooktop User Manual


 
17
TECHNICAL INFORMATION
FOR THE INSTALLER
In order to install the cooktop into the
kitchen fixture, a hole with the dimen-
sions shown in fig. 13 has to be made,
bearing in mind the following:
within the unit, between the bottom
of the cooktop and the upper sur-
face of a shelf there must be a clear-
ance of at least 30 mm.
It is absolutely essential that you
place a separator between the base
of the cooktop and the built-in unit
or the oven;
the cooktop must be kept no less
than 200 mm away from any side
wall (fig. 13).
the hob must be installed at least 60
mm from the wall.
480
60
0
–2
560
200
0
–2
680
500
650 mm
450 mm
INSTALLATION IN KITCHEN
CABINET WITH DOOR (fig. 14)
It is recommended that a 30 mm clear-
ance be left between the cooktop and
the fixture surface (fig. 14).
30 mm
Space for
connections
Clearance
Door
Figure 12
Figure 14
Figure 13
there must be a dis-
tance of at least
650 mm between
the hob and any
wall cupboard or
extractor hood posi-
tioned immediately
above (see fig. 12).
if the hob is installed over a built-in
oven, there must be a distance of at
least 30 mm between the two appli-
ances. The two appliances should be
connected to the gas supply with
independent connections.