Cecilware BC2 Coffeemaker User Manual


 
4
INITIAL PRIMING – Filling of Tank
The BC Brewers are shipped with the Thermostat in the OFF
position. Do not turn Thermostat to the ON
position until the Brewer has been fully primed.
a. Turn water supply on and check for leaks at the water inlet connections. Tighten compression fitting if
necessary.
b. Turn on power to the Brewer. The Brewer will automatically start filling. After 6 minutes the filling cycle will
stop and the thermostat should be turned clockwise to the full ON
position. Allow approximately 20 minutes for
the brewer to reach full brewing temperature (197'-203').
When the GREEN READY LIGHT comes ON
the brewer is ready to brew the next batch of coffee.
NOTE: Before proceeding further, make sure the sample Filter pack has been removed from the
funnel.
CHECKING BREW CYCLE OUTPUTS
.
The BC-Series brewers are factory preset to deliver the proper amount of brewing water for the 12 cup,
24 cup and 36 cup brew cycles. Nevertheless, it is a good practice to check the output levels prior to
brewing the first batch of coffee.
BC1 and BC2: Full 36 cups (3 decanters) per brew cycle with a 20% by-pass.
BC120 and BC240: Selectively 12 cups (1 decanter) or 24 cups (2 decanters) per brew cycle.
No by-Pass.
BC301 and BC302: Selectively 12, 24 and 36 cups per brew cycle with a 20% by-pass for the 36 cup
cycle only.
TO START A BREW CYCLE:
Turn Warmer Switch to the ON position. The Warmer Switches also double as CYCLE STOP switches.
With Funnel and Carrier in place activate GREEN BREW switch.
On BC120, BC240, BC301 and BC302 brewers first activate brew switches marked 12 cups and then
check output. Do the same with the 24 cup brew switch and the 36 cup brew switch for the BC301 and
BC302 units.
NOTE: 12 cups equal 1 full decanter.
If necessary adjust the timer(s) to increase or decrease output levels. See Timer adjustments.
COFFEE BREWING INSTRUCTIONS
Place filter paper into brew basket and add finely ground coffee as per chart below:
MODEL# CUPS BREWED RECOMMENDED COFFEE
AMOUNT
TOTAL BREW TIME
Single BC120 12 / 24 Cups 2 oz./ 4 oz. 3.0 / 4.5 Minutes
Single BC240 12 / 24 Cups 2 oz./ 4 oz. 3.0 / 4.5 Minutes
Single BC1 36 Cups 6 oz. 6.0 Minutes
Twin BC2 2 x 36 Cups 2 x 6 oz. 6.0 Minutes
Single BC301 12 / 24 / 36 Cups 2 oz./ 4 oz./ 6 oz. 3.0 / 4.5 / 6.0 Minutes
Twin BC302 2 x (12 / 24 / 36 Cups) 2x (2 oz./ 4 oz./ 6 oz.) 2x (3.0 / 4.5 / 6.0 Minutes)
Insert brew funnel back into brewer and position empty carriers under brew funnels. With Warmer
Switches on (lit), depress Green Brew Switches. Total brew time will vary according to cups selected.
After funnel stops dripping, remove and empty funnels.
Warning:
Remove Brew funnel ONLY after it has stopped dripping.