Cecilware BC2 Coffeemaker User Manual


 
6
REMOVE JUMPER FOR 240V
2. TIMER ADJUSTMENT PROCEDURE
Remove the top cover to access the brew timer(s).
To INCREASE output: turn timer knob a small increment CLOCKWISE.
To DECREASE output: turn timer knob a small increment COUNTER-CLOCKWISE.
Check output level in carrier.
BCI, BC2 BC120, BC240 BC301, BC302
Single Timer (L264A) Dual Timer (58026) 120 Triple Timer
Dual Timer (58027) 240 (Dual Voltage)(L410C)
3. THERMOSTAT ADJUSTMENT
The BC Brewers are factory set to deliver hot brewing water at 200' F. The water temperature, at the
spray head, should be between 195' F-203' F with the thermostat knob at its maximum clockwise position.
If adjustment is necessary, proceed as follows:
a. To RAISE water temperature, turn temperature control knob to
its maximum clockwise position. Remove the knob and locate
slotted adjustment screw inside hollow thermostat shaft. Using a
narrow-bladed screwdriver, engage slotted adjustment screw
and turn it 1/4 turn counter-clockwise. The thermostat will cut in
and the Green ready light will go off. When Green ready light
comes on after a few minutes, measure temperature and repeat
if necessary.
b. To LOWER water temperature, simply turn knob one notch counter-
clockwise to next lower number on dial.
HINT: To measure water temperature accurately, remove the spray-head for a solid water stream.
4. WATER FLOW RATE ADJUSTMENT
Locate adjustment screw on valve (as show here).
Using an Allen Key or a flat screwdriver, rotate ¼ turn at a time,
Clockwise (CW) to decrease water flow rate or
Counter-Clockwise (CCW) to increase water flow rate.
Check water flow output after each ¼ turn.
The SINGLE
DISPENSE VALVE is factory adjusted to dispense
0.6 oz./sec. of water during the brew cycle (spray duration).
The DOUBLE/
DILUTION DISPENSE VALVE is factory adjusted,
on both sides, to dispense 0.22 oz./sec of water
during dilution cycle.