Cleveland Range 24CGA10.2 Electric Steamer User Manual


 
PROBLEM:
24CGA6
24CGA10.2
Steamer won't fill
with the handle in
the on position
Is there power
to the steamer?
Connect
power to the
steamer
No
Is there water to
the steamer?
Yes
Supply
water to the
steamer.
No
Is there 120 VAC
between the
terminals H and N
on the watr level
board?
Yes
Adjust or
replace on/off
micro switch
No
Is there 120 VAC
between terminals
Fill and N on the
water board?
Yes
With the wire
removed from the HI
terminal on the water
level board, is there
120 VAC between
terminals Fill and N?
No
Replace the
water level
board.
No
Is there debris on
the HI probe in the
probe assy?
Yes
Replace the
wire to the HI
probe.
No
Clean or
replace the
probe assy.
Yes
Is there 120 VAC
across the coil of
the fill solenoid?
Yes
Adjust or
replace the on/
off micro switch
No
Is water leaving
the fill solenoid?
Yes
Replace the fill
solenoid.
No
Does the manual
drain valve close
completely?
Yes
Clean or
replace the
drain valve.
No
Yes
Steamer won't
fill