PRESSURE RELIEF VALVE
TESTING PROCEDURE
The pressure relief valve (optional on kettles) must
be checked at least twice a year as part of the
normal maintenance performed.
1. Open steam valve and preheat kettle.
2. Stand to the side of the pressure relief valve
discharge tube and pull ring three or four
times to insure free movement. Hold valve
open for two seconds each time, insuring
there is rapid steam escape each time.
3. If valve appears to be sticking replace
pressure relief valve. If foreign material is
discharged, replace pressure relief valve and
eliminate the source of contamination.
STEAM TRAP
To remove line condensate that forms inside the
steam jacket, each kettle should be equipped with
a steam trap in the line of the kettle outlet to the
drain. A good steam trap at startup releases air
and wet steam into the drain line for a few
minutes, then holds the steam jacket. During
cooking, the trap periodically releases
accumulated condensate. If the kettle's cooking
performance becomes inadequate after long use,
replacement of the steam trap with a new one may
restore kettle operation to peak efficiency.
MARINE LOCK
Inspect lock at least twice yearly.
1. Check for excessive play or wear on pivot.
Adjust or replace as required.
2. Insure lock is catching over the centre of the
stop pin and not bent to one side or the other.
Adjust or replace as required.
WARRANTY
Our Company supports a worldwide network of
Maintenance and Repair Centers. Contact your
nearest Maintenance and Repair Centre for
replacement parts, service, or information
regarding the proper maintenance and repair of
your cooking equipment
In order to preserve the various agency safety
certification (UL, NSF, ASME/Ntl. Bd., etc.), only
factory-supplied replacement parts should be
used. The use of other than factory supplied
replacement parts will void warranty.
WARNING
Kettle will be hot. Use gloves for protection.
MAINTENANCE
ALL SERVICE MUST BE PERFORMED BY A
QUALIFIED SERVICE TECHNICIAN.
This kettle requires very little preventative maintenance other than daily cleaning.
The pressure relief valve must be tested twice a year.
11