Cleveland Range SEL-30-T1 Fryer User Manual


 
3
DPK
(OPTION)
39"
991mm
35"
889mm
(RIM
HEIGHT)
71"
1804mm
75
28 3/4"
731mm
(PAN
SURFACE)
A
B
(PAN SURFACE)
41"
1042mm
H C
25 15/16"
(659mm)
3 7/8" (99mm)
C
5 1/4"
(134mm)
(FAUCET
OPEN)
30"
(762mm)
5"
(127mm)
(MANUAL
TILT HANDLE)
D
RECOMMENDED FLOOR
SLOPE 1" (26mm) IN 4' (1220mm)
FLOOR DRAIN
PIPE DRAIN RECOMMENDED
MINIMUM VALVE SIZE PLUS 1" (26mm)
4" (102mm) MINIMUM
6" (153mm) RECOMMENDED
DPK
(OPTION)
LEG LOCATION &
SUGGESTED FLOOR DRAIN DETAIL
MODEL
SEL-30-T1
SEL-40-T1
A
39 1/8"
(994mm)
51 1/8"
(1299mm)
ELECTRICAL SUPPLY
RIGHT:
3" (77mm) (manual tilt)
0" (power tilt)
LEFT: 0", REAR: 0"
SEL-30-T1
390 LBS. (178 KG.)
SEL-40-T1
410 LBS. (187 KG)
APPROXIMATE
SHIPPING WEIGHTS
CLEARANCE
APPROVALS
UL CSA
SPECIFICATIONS
DIMENSIONS CAPACITIES
B
24 1/2"
(623mm)
36 1/2"
(928mm)
F
18 1/4"
(464mm)
24 1/4"
(616mm)
G
5 3/4"
(146mm)
5 3/4"
(146mm)
C
31 3/4"
(807mm)
43 3/4"
(1112mm)
D
12"
(305mm)
18"
(458mm)
In 4 oz. servings. Other sizes may be calculated.
30 gallons / 115 Liters.............960
40 gallons / 150 Liters...........1280
KW
12
16
18
24
208V
AMPS
3ph
33.3
44.4
50
66.7
1ph
57.7
77
86.5
NA
240V
AMPS
3ph
28.9
38.6
43.4
57.8
480V
AMPS
3ph
14.5
19.3
21.7
28.9
1ph
50
66.7
75
NA
WATTAGE
Standard
High
Standard
High
MODEL
SEL-30-T1
SEL-40-T1
9 1/2" (241mm)
(PAN DEPTH)
FLOOR
DRAIN
GRATE
12" x 20"
(305mm x
508mm)
H C
2 1/4"
(57mm)
7/16"Ø, 3 HOLES
ON 3 1/8" (80mm) B.C.D.
FLANGED FOOT DETAIL
(REAR LEGS ONLY)
120 120
4 7/8" (124mm)
9/16" (15mm)
1" (26mm)
(MAXIMUM
ADJUSTMENT
2" (51mm)
SPECIFICATION DRAWING