Cleveland Range (T) MKDL-150-T (-CC) Hot Beverage Maker User Manual


 
MRC 7000 Controls Drawing (1 pen)
Pen
Display
Pen1 key -
AUTO/MAN
AUTO
MAN
SCROLL Key
UP Key
DOWN Key
˚C
˚F
˚U
SP
MAN OUT1 OUT2 ALRM
Manual
Heat
Output 1
Cooling
Output 2 Alarm
Setpoint
Minus Sign
˚C
˚F
U
SP
MAN OUT1OUT2ALRM
BYPASS ACTIVE
BYPASS ACTIVE
HEAT AUTO COOL
OFF
BYPASS ACTIVE
HEAT AUTO COOL
OFF
MIXER KETTLE
OPERATION USING
MRC 7000 (1 PEN)
Note: Temperature probe on
mixer bridge must be covered
with a minimum of three inches of
product to function correctly.
1. Turn MAIN POWER switch to
"ON".
2. Turn HEAT/COOL switch to
"OFF/AUTO".
3. Turn ACTIVE/BYPASS switch to
"ACTIVE".
4.
Open steam valve completely.
5. On controller keypad push
and hold key " " or
" " until desired temperature
is set.
6. To
start
: push scroll key
" " until "
CtrL
" is displayed.
7. Push down key " ".
8. To
stop
: push scroll key
" " until "
OFF
" is displayed.
9.
Push down key " ".
NOTE: For twin kettles, the
MRC 7000 will control the kettle
the mixer is in.
If the unit is used continually it
may be simpler to control the
"
ON/OFF
" function with the
following steps:
1. Keep HEAT/COOL switch at
"OFF/AUTO".
2. To stop turn ACTIVE/BYPASS
switch to "BYPASS".
3. To change temperature
setting push and hold key
" " or " " until desired
temperature is set.
4. To start, turn ACTIVE/BYPASS
switch to "ACTIVE".
OFF ON